Pb-Free Assembly - Process
Nitrogen is used for reflowing the PCB’s mostly for Pb-Free Assembly through Nitrogen tank plant which consists of Cryo Cylinder followed by a vaporizer. The purpose of vaporizer is to convert the cold liquid Nitrogen in the Cryo cylinder into gas Nitrogen. The tanks are normally filled by the supplier of Nitrogen by bringing the truck to the plant location and then pumping cold fluid Nitrogen into the cryo-tank as and when needed.
When Pb-Free Assembly is done while Nitrogen is being used, the nitrogen vaporizes at minus 196 degree Celsius inside the vaporizer and becomes a gas. Then this nitrogen gas is transported in the special copper tubing to the reflow oven.
Usually the cold nitrogen is applied directly into the reflow zone where the temperature could reach as high as 250 – 270 degrees Celsius. So the delta T is quite high, when the nitrogen temperature is as low as 10 -15 degrees Celsius. This can cause some temperature regulation problems and finally result in large variation in soldering temperature which can be avoided by running nitrogen through pre heating section in the reflow oven before the actual reflow process itself. Other way to reduce the temperature variation could be to run the nitrogen from the plant to the reflow oven through supply tubes that are at least 50 meters or more in length.